• Extract files from the SpeedcamUpdates zip package. Usa's largest state school in 1861. If the file you have downloaded is not a ZIP file means the file is already decompressed, and you can continue with the next step of this installation instructions. First of all, be sure you got the update file for your iGO 8 device, downloaded from SpeedcamUpdates.com. • Copy into your iGO 8 device, the extracted files before, into the memory card, in a folder called './iGO8/Content/Speedcam'. If still haven't got it, you can get it now filling the form you see on this page.
Enter the New World of Easergy Studio Easergy Studio will make your life easier by providing integrated configuration and monitoring features. It has an intuitive and versatile interface with file management facilities. The current Easergy Studio brings enhanced usability while preserving the rich features of its previous versions. Mozilla firefox for windows server 2008. Easergy Studio Software Request A link to download the Easergy studio software can be found by clicking Documents & Software in the Downloads menu. Installation Guideline for Upgrading (Maintaining Installed Data Models) As you can run only one Easergy Studio installation on your PC, you first need to remove an older version. Use Windows® Control Panel to call the Easergy Studio setup wizard.
Press ‘Yes’ when asked whether you want to remove the application and all pertaining features. Press ‘No’ when asked whether you want to remove the data models from your disk. The wizard will remove all programs of Easergy Studio.
Asian paints colour visualizer software. Close the wizard, close the Control Panel. Run the new Easergy Studio installation executable.
Select all options as done for the installation before. Do not agree to launch the Data Model Manager. As soon as the wizard finishes, you are able to launch Easergy Studio and open your existing projects. User Programmable Curve Tool Application Software: The User Programmable Curve Tool provides the following features:.
Alstom Micom S1 Software
Creation of user-defined curves and flexible download/upload of operating and reset curves into/from Easergy MiCOM Px4x range of relays. User-friendly graphical user interface for easy creation and visualization of curves either by inputting formula or data points. MiCOM P746 Remote HMI PC Application Software (Included in Easergy Studio): The Easergy MiCOM P746 remote PC HMI allows the user to display the Easergy MiCOM P746 Busbar topology, associated measured analogue quantities and DDB (digital data bus) status information such as circuit breaker and isolator positions and alarms.
Overview This advisory provides mitigation details for a vulnerability affecting the Schneider Electric MiCOM S1 Studio Software. Independent researcher Michael Toecker of Digital Bond has identified an improper authorization vulnerability in the MiCOM S1 Studio Software using the Microsoft Attack Surface Analyzer tool. The vulnerability was disclosed to vendors prior to the 2013 Digital Bond S4 Conference and then presented at the conference. The function of MiCOM S1 Studio Software is to allow users to modify or manage the configuration parameters of electronic protective relays. Affected Products The following Schneider Electric MiCOM S1 Studio Software products are affected:.
Micom S1 Studio Software
MiCOM S1 Studio Software, all versions. Impact Successful exploitation of this vulnerability may allow an attacker with read/modify user permissions for the MiCOM S1 Studio file system to affect the availability of the application. Unauthorized attackers can then access the MiCOM S1 Studio executable files. This vulnerability can affect products deployed in the energy, water and wastewater, and critical manufacturing sectors. Impact to individual organizations depends on many factors that are unique to each organization. ICS-CERT recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation. Background Schneider Electric is a Europe-based company that maintains offices in 190 countries worldwide.
Their products address various markets including renewable energy, process control, monitoring and control, motor controls, lighting controls, electrical distribution, and security systems. The affected product, MiCOM S1 Studio Software, allows users to modify or manage the configuration parameters of electronic protective relays. According to Schneider Electric, MiCOM S1 Studio Software is deployed across several sectors including energy, water and wastewater, and critical manufacturing. Vulnerability Characterization Vulnerability Overview Improper Access Control The MiCOM S1 Studio Software does not limit user access to its installed executables to only authenticated administrative users. A malicious user with any level of access to the local system could replace executables within the MiCOM S1 Studio Program Files directory with malicious files. When the MiCOM S1 Studio application is run, the malicious executable would be run instead. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality with the local system and a disruption in communications with other connected devices.
In addition, a Windows Service running under LocalSystem is located within this directory as well. Replacing the associated executable, in this case, would allow lower privileged users to escalate their privileges to an administrator level on the system. CVE-2013-0687 has been assigned to this vulnerability.
Micom S1 Studio Software Download
A CVSS v2 base score of 6.0 has been assigned; the CVSS vector string is. Vulnerability Details Exploitability This vulnerability is not exploitable remotely and cannot be exploited without access to the local system by an authorized user. Existence of Exploit No known public exploits specifically target this vulnerability. Difficulty An attacker with a high skill would be able to exploit this vulnerability. Mitigation Schneider Electric has produced a to address the MiCOM S1 Studio Software vulnerability and provide mitigation strategies. ICS-CERT encourages asset owners to take additional defensive measures to protect against this and other cybersecurity risks. Minimize network exposure for all control system devices.
Critical devices should not directly face the Internet. Locate control system networks and remote devices behind firewalls, and isolate them from the business network. When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPN is only as secure as the connected devices. ICS-CERT also provides a section for on the ICS-CERT Web page. Several recommended practices are available for reading and download, including. ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to taking defensive measures.
Additional mitigation guidance and recommended practices are publicly available in the ICS-CERT Technical Information Paper,. Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents. CWE-284: Improper Access Control, Web site last accessed April 10, 2013. NVD, NIST uses this advisory to create the CVE Web site report. This Web site will be active sometime after publication of this advisory Contact Information For any questions related to this report, please contact the NCCIC at: Email: Toll Free: 1-888-282-0870 For industrial control systems cybersecurity information: or incident reporting: The NCCIC continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.